    NEWS CENTER

    • 夏天使用防爆空壓機要注意?
    • 本站編輯:杭州天源氣超濾設備工程有限公司發布日期:2022-03-09 16:14 瀏覽次數:

    夏季防爆空壓機常見的問題就是高溫,要勤換空氣濾芯、機油過濾器、油分濾芯,保證潤滑油的量和品質,經常清洗冷卻器、斷油閥保證不堵塞,注意空壓房室內的通風狀況,盡量降低防爆空壓機房的溫度,能維持在35度以下。

    電氣方面的連接線,接觸器等等要經常檢查,要防止過熱短路。防爆空壓機冷卻潤滑油的更換時間取決于使用環境、濕度、塵埃和空氣中是否有酸堿性氣體。

    注意冷卻器,務必保證冷卻器正常工作,能提供良好的冷卻效果。

    注意及時檢查、發現防爆空壓機機械故障,比如進排氣閥是否完好、用手盤電動機和主機要靈活無卡死現象等。

    經常檢查潤滑油系統,能及時發現潤滑油變質、油位不合適、防爆空壓機內部系統壓差過大等問題。

    若是水冷式防爆空壓機,請務必保證冷卻水的溫度合格、水流暢通、流量足夠;若是風冷式防爆空壓機,請確保整個工作環境的空氣流通性,必要時可配備散熱系統,周圍不能有高溫熱源,空氣過濾器要按時吹干凈,防止堵塞,防止增加空氣阻力5、每天按時排放氣罐和精密過濾器冷凝水。

    The common problem of explosion-proof air compressor in summer is high temperature. Frequently change the air filter element, oil filter and oil separation filter element to ensure the quantity and quality of lubricating oil. Often clean the cooler and oil cut-off valve to ensure that they are not blocked. Pay attention to the ventilation condition in the air compressor room and try to reduce the temperature of explosion-proof air compressor room, which can be maintained below 35 degrees.

    Electrical connection lines, contactors, etc. should be checked frequently to prevent overheating and short circuit. The replacement time of cooling lubricating oil of explosion-proof air compressor depends on the use environment, humidity, dust and whether there is acid-base gas in the air.

    Pay attention to the cooler and ensure that the cooler works normally and can provide good cooling effect.

    Pay attention to timely check and find the mechanical faults of explosion-proof air compressor, such as whether the inlet and exhaust valves are intact, and the motor and main engine should be flexible without jamming by hand.

    Regularly check the lubricating oil system to find out the problems such as deterioration of lubricating oil, improper oil level, excessive differential pressure in the internal system of explosion-proof air compressor and so on.

    For water-cooled explosion-proof air compressor, please ensure that the temperature of cooling water is qualified, the water flow is smooth and the flow is sufficient; If it is an air-cooled explosion-proof air compressor, please ensure the air circulation of the whole working environment. If necessary, it can be equipped with a heat dissipation system. There can be no high-temperature heat source around. The air filter should be blown clean on time to prevent blockage and increase air resistance. 5. Discharge the condensate of the air tank and fine filter on time every day.